PAM XIAMEN offers 3″ Silicon Wafer-17 as follows, while silicon wafer list includes, but not limited to the following.
Silicon wafers, per SEMI Prime,
P/P 4″Ø×300±25µm,
p-type Si:B[100]±0.5°, Ro=(5-10)Ohmcm,
TTV<10µm, Bow<40µm, Warp<40µm,
Both-sides-polished, SEMI Flats (two),
Primary Flat length 32.5±2.5mm, orientation 110±1°。
Secondary Flat length 18±2mm, orientation 90°±5°
Sealed in Empak cassette
For [...]
2019-11-26meta-author
PAM XIAMEN offers LaSrAlO4 Strontium Lanthanum Aluminate Crystal Substrates.
Main Parameters
Crystal structure
M4
Growth method
Czochralski method
Unit cell constant
a=3.756Å c=12.63 Å
Melt point(℃)
1650
Density
5.92(g/cm3)
Hardness
6-6.5(mohs)
Dielectric constants
ε=16.8
Size
10×3,10×5,10×10,15×15,20×15,20×20
Ф15, [...]
2019-03-14meta-author
Both PAM1002 and PAM0502 are single channel counting module based on CZT detector.They integrated CZT detectors,which sizes are 10x10x2mm³, 5x5x2mm³ or others, high gain charge sensitive amplifier and SK shaping circuit.
1. Specification of Single Photon Channel Counting Module
Dimension
37×18×5mm3
Weight
5.7g
Energy range
50KeV~1.5MeV
Measurement accuracy
<±10%@137Cs
Dose rate range
0.1uSv/h~1.5mSv/h
Output impedance
50Ω
Operating temperature
-20℃-+40℃
Power
<0.01W
Time [...]
2019-04-23meta-author
Terahertz (THz) wave generation technology is widely used in fields such as terahertz sensing, safety imaging, non-destructive material testing, and high-speed terahertz wireless data communication. Optical heterodyne is a method of achieving continuous tunable terahertz wave emission by mixing beat frequency signals of two [...]
2023-12-11meta-author
PAM XIAMEN offers (100) orientation Silicon Substrates.
Below is just a small selection. Let us know if you can use or if we can quote you on another spec.
Item
Material
Orient.
Diam
(mm)
Thck
(μm)
Surf.
Resistivity
Ωcm
Comment
PAM2929
n-type Si:P
[100]
4″
525
P/E
43657
SEMI Prime, 2Flats, Empak cst
PAM2930
n-type Si:P
[100]
4″
525
P/E
43657
SEMI Prime, 2Flats, Empak cst
PAM2931
n-type Si:P
[100]
4″
224
P/E
5–10
SEMI Flats (two), Empak cst, Cassette of [...]
2019-02-22meta-author
PAM-PA01 series are pixel electrode structured detectors based on CZT crystal. They can detect X-ray, γ-ray and imaging. They have a high energy and space resolution.
1. Specification of CZT High Resolution Pixel Detector
Material
CdZnTe
Density
5.8g/cm3
Volume resistance
>1010Ω.cm
Dimensions
10.0×10.0mm2
Thickness
2.0mm
5.0mm
Pixel size
1.1×1.1mm2
Pixel array
8×8
Electrode material
Au
Operation temperature
-20℃-+40℃
Energy range
20KeV~700MeV
20KeV~700MeV
Energy resolution(22℃)
<6%@59.5KeV
<4.5%@122KeV
<3%@662KeV
Defective pixel(DP)
10℃~40℃
Storage temperture
20%-80%
Remarks
Customized available
2. Spectrum of [...]
2019-04-24meta-author